EXPERIMENT COVERAGE
• The following Power Electronics Experiments are covered used the various related training modules.
• These modules enable students to investigate a wide range of power electronics syllabus practical topics. Students investigate each topic with hands
on experimentation, circuit construction and evaluation tasks which are provided in the experimental manual/workbook.
• Each module is equipped with clearly labeled block diagram and built-in connection interface and test points.
TEACHING MODULE SPECIFICATION
•
THREE PHASE POWER SUPPLY UNIT - MODEL: PSU-3P-02A
• Fixed and variable AC supplies
• Provided with start/stop push button and emergency push button
• Three phase AC adjustableoutput : 3 x 0 ~ 450VAC with Voltmeter Indicator
• Three phase AC fixed output : 240/415VAC (10A Max)
• Circuit breaker protection
• Power Requirement : 240/415V, 50Hz
• Connection via 4mm safety sockets
• Fuse protection
•
POWER CIRCUIT BREAKER MODULE - MODEL: PCB-3P-01
• Three phase ON/OFF switch with auxiliary contact (NC) for transmission line module
• Can be controlled manually using ON/OFF push button or externally via switching contact
• Input Voltage : 415VAC/50Hz
• Coil Voltage : 240VAC/50Hz
• Current rating : 9A Max.
• Connection via 4mm safety sockets
•
MEASUREMENT METER MODULE - MODEL: PM-05
• Input voltage : 240VAC/50Hz
• AC Voltmeter x 2
• Measurement range : 0 ~ 500VAC
▪ Size : 78mm x 42mm
• AC Ammeter x 2
• Measurement range :
▪ 0 ~ 10A (AC)
▪ Size : 78mm x 42mm
• Connection via 4mm safety sockets
•
DIGITAL MULTIFUNCTION ELECTRICAL METER MODULE - MODEL: ELC-DM-01
• Measurement: V, KV, Hz, A, KA, S, KW, KVAR, KVA, KWH, KVRH
• AC voltage measurement : 20 ~ 300VAC (phasevvoltage), accuracy 0.5%
• AC current measurement: 5A AC (each phase & neutral), accuracy 0.5%
• Active power (KW), reactive power (KVAR), apparent power (KVA), accuracy 1%
• Power factor: each phase and total, accuracy 1%
• Frequency measurement: 45~65Hz, accuracy 0.5%
• Energy measurement: active energy accuracy 1%, reactive energy 2%
•
THREE PHASE TRANSFORMER MODULE - MODEL: TFB-01
• Transformer for feeding the transmission line model 415VAC
• Primary: 415VAC with tapping at 240VAC
• Secondary: 380VAC with tapping at +5%, -5%, -10%, -15% in star connection
• Connection via 4mm safety sockets
•
TRANSMISSION LINE MODULE - MODEL: TLB-02
• Simulate 360km transmissionline
• Three resistance, inductance and capacitance with 3 steps variable per phase.
• Connection via 4mm safety sockets
•
RESISTIVE LOAD MODULE - MODEL: SRB-LD-02
• Three resistance with possibility to connect in star/delta or parallel.
• Resistance with 7 steps variable per phase.
• Resistance : 200 ~ 800 ohm.
• Input voltage : Three phase AC 240V/415V (Delta/Star) 50Hz.
• Rated current: 1A Max.
• Power: 900W Max.
• Connection via 4mm safety sockets
•
INDUCTIVE LOAD MODULE - MODEL: SIB-LD-02
• Three inductance with possibility to connect in star/delta or parallel.
• Inductance with 7 steps variable per phase.
• Inductance: 0.2 ~ 2H.
• Input voltage: Three phase AC 240V/415V (Delta/Star) 50Hz.
• Rated current: 1.2A Max.
• Power: 900VAR
• Connection via 4mm safety sockets
•
CAPACITIVE LOAD MODULE - MODEL: SCB-LD-02
• Three capacitance with possibility to connect in star/delta or parallel.
• Capacitance with 7 steps variable per phase.
• Capacitance: 1 ~ 16uF
• Input voltage: Three phase AC240V/415V (Delta/Star) 50Hz.
• Rated voltage: 450V Max.
• Power: 900VAR
• Connection via 4mm safety sockets
•
TRANSMISSION LINE CAPACITOR MODULE - MODEL: TLB-02
• Three phase in star connection, 2.5 μF each, corresponds to 50% of the operating apacitance of transmission line module.
• Input voltage: Three phase AC240V/415V 50Hz.
• Rated voltage: 450V Max.
• Connection via 4mm safety sockets
•
EARTH FAULT COMPENSATION MODULE - MODEL: SRB-LD-02
• Inductance with 10 tapping for earth fault compensation in transmission line module.
• Inductance: 5mH ~ 2H.
• Rated voltage: 240VAC 50Hz.
• Rated current: 0.5A.
• Connection via 4mm safety sockets
•
OVERCURRENT & EARTH FAULT PROTECTION MODULE - MODEL: EPD-01
• Earth Fault Protection
• Connection via 4mm safety sockets
•
SIMULATION SWITCH MODULE - MODEL: TFB-01
• Push Button (NO) x 2
• Push Button (NC) x 1
• Emergency Button (NC) x 1
• Toggle Switch (2 pole) x 1
• Connection via 4mm safety sockets
•
EXPERIMENT PANEL FRAME - MODEL : MR-002
• Aluminium/Metal construction
• 2 or 3 layer
• Mounting of the training modules
• Dimension 1050mm (L)
•
4mm SAFETY CONNECTING LEADS - MODEL : 4MM-SCL
• 4mm safety connecting leads set
MANUAL & ACCESSORIES
• Operation / User Manual x 1
• Lab Experiment Manual (with answer) x 1
• U-Link x 1 set