TEACHING MODULE SPECIFICATION & EXPERIMENT COVERAGE
MODULE One :
(i) Elementary Impedance Matching Network
•
L-Type Matching Network (Operational Frequency: 900 MHz)
•
PI (Π) – Type Matching Network (Operational Frequency: 900MHz)
•
T-Type Matching Network (Operational Frequency: 900 MHz)
(ii) Impedance Matching Network
•
Tapped Capacitor Matching Network (Operational Frequency: 900MHz)
•
Tapped Inductor Matching Network (Operational Frequency: 900MHz)
•
Low Quality Factor Matching Network (Operational Frequency: 900MHz)
MODULE Two :
(i) One Stage Low Noise Amplifier
•
Measurement of Frequency Response (Operational requency: 890 ~ 915 MHz)
•
Measurement of Noise Figure (Operational Frequency: 890 ~ 915MHz; Noise Figure: 2dB)
•
Measurement of 1dB Compression Point (Operational Frequency: 890 ~ 915MHz; P(1 dB) : -10 dBm)
(ii) Two Stages Low Noise Amplifier
•
Measurement of Frequency Response (Operational Frequency: 890 ~ 915 MHz)
•
Measurement of Noise Figure (Operational Frequency: 890 ~ 915MHz; Noise Figure: 2dB)
•
Measurement of 1dB Compression Point (Operational Frequency: 890 ~ 915 MHz; P(1 dB) : -13 dBm ~ -18dBm)
MODULE Three:
(i) Two Stages Pre-Amplifier
•
Measurement of Frequency Response (Operational Frequency: 800 ~ 1000 MHz)
•
Measurement of Noise Figure (Operational Frequency: 800 ~ 1000MHz; Noise Figure: 3dB)
•
Measurement of 1dB Compression Point (Operational Frequency: 800 ~ 1000 MHz; P(1 dB) : -5dBm)
(ii) Power Amplifier
•
Measurement of Gain Flatness (Operational Frequency: 700 ~ 1000 MHz; Gain Flatness: ±2.5dB)
•
Measurement of 1dB Compression Point (Operational Frequency: 700 ~ 1000 MHz; P(1dB): 15dBm)
•
Measurement of OIP3 (Operational Frequency: 915 MHz; IP3: 25dBm)
•
Measurement of Harmonics (Operational Frequency: 915 MHz)
MODULE Four:
(i) Colpitts & Hartley Oscillators
•
Frequency: 800 ~ 900 MHz)
•
Measurement of Phase Noise (Phase Noise: -90 ~ -110dBc/ Hz)
•
Measurement of Gain Factor & Variable Bandwidth (Gain Factor: 10 ~ 14 MHz/V; Variable Bandwidth: 50 ~ 70 MHz)
(ii) Common Collector Colpitts Oscillator
•
Measurement of Frequency & Output Power (Oscillator Frequency: 750 ~ 850 MHz)
•
Measurement of Phase Noise (Phase Noise: -90 ~ -110dBc/ Hz)
•
Measurement of Gain Factor & Variable Bandwidth (Gain Factor: 8 ~ 10 MHz/V; Variable Bandwidth: 40 ~ 50 MHz)
MODULE Five:
(i) Phase Locked Loop Controller
•
LCD & Keypad Testing (Locked Frequency Display; Locked Status Detection)
•
MB15E03L Control Signal Testing (Locked Frequency: 800MHz, 812MHz, 825MHz)
(ii) Phase Locked Loop
•
Measurement of Frequency Response for Loop Filter (-3dB Frequency: 600 Hz)
•
Measurement of PLL (Locked Frequency: 800MHz, 812MHz, 825MHz)
•
Measurement of FM Signal (Audio Signal: 1 kHz, Modulation Bandwidth: 100 ~ 150 kHz)
MODULE Six:
(i) Diode Mixer
•
Measurement of Conversion Gain (Radio Signal: 795 ~ 895MHz or 1800 ~ 1900MHz; Local Signal: 915MHz or 1780MHz; Intermediate Signal: 20 ~ 100MHz)
•
Measurement of 1dB Compression Point (Radio Signal: 845MHz or 1850MHz; Local Signal: 915MHz or 1780MHz; Intermediate Signal: 70MHz)
•
Measurement of Isolation (Local Signal: 840 ~ 990MHz or 1705 ~ 1855MHz)
(ii) Transistor Mixer
•
Measurement of Conversion Gain (Radio Signal: 877 ~ 977MHz or 910 ~ 1010MHz; Local Signal: 857MHz or 850MHz;
Intermediate Signal: 20 ~ 100MHz or 60 ~ 160MHz)
•
Measurement of 1dB Compression Point (Radio Signal: 927MHz or 910MHz; Local Signal: 857MHz or 850MHz; Intermediate Signal: 70MHz or 60MHz)
•
Measurement of Isolation (Local Signal: 782 ~ 932MHz or 840 ~ 990MHz)
MODULE Seven:
(i) Low Pass & High Pass Filter
•
Measurement of Frequency Response (Operational Frequency: 500 ~ 1500MHz; Low Pass -3dB Freq: 900MHz; High Pass -3dB Freq: 900MHz)
(i) Bandstop & Bandpass Filters
•
Measurement of Frequency Response (Operational Frequency: 500 ~ 1500MHz; Bandstop Center Freq: 900MHz, Bandwidth: 200MHz; Bandpass Center Freq:
70MHz, Bandwidth: 20MHz)
MODULE Eight:
(i) IF FM Demodulation Circuit
•
Measurement of IF FM Demodulation Circuit (Intermediate Signal: 70.7MHz, Modulation Bandwidth: 20 kHz)
(ii) Audio Signal Processing Circuit
•
Measurement of Pre-emphasis & Compression for Audio Signal (Audio Signal: 20Hz ~ 50Hz)
•
Measurement of De-emphasis & Decompression for Audio Signal (Audio Signal: 20Hz ~ 50Hz)
TEACHING MODULE SPECIFICATION (OPTIONAL)
POWER SUPPLY MODULE
•
Variable Voltage Output:
•
0 ~ ± 12VDC/0.5A
•
Fixed Voltage Output:
•
± 5VDC(0.3A)
•
± 12VDC(0.3A)
•
Triple Bipolar Voltage Outputs
•
Constant Voltage Operations
•
Low Ripple & Noise
•
Connection using 4mm sockets
FUNCTION GENERATOR MODULE
•
Two signal output ports
•
Waveforms: Sine, Triangle, Square, TTL Pulse
•
Amplitude: >10Vpp
•
Impedance: 50Ω ± 10%
•
Duty Control: 30% - 60%
•
Frequency Range:
o
10Hz ~ 100kHz (4 Ranges)
o
100Hz ~ 1MHz (4 Ranges)
•
Accuracy: ± Time Base Count ± Count
•
Time Base: 60Hz Oscillation Frequency
•
Resolution: 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz
•
Frequency Control: Separate Coarse & Fine Tuning
•
Large 0.5” LED Display
•
Overload Protection
•
Built-in 6 Digits Frequency Counter
•
Connection using 4mm sockets
•
Power Requirements: 240VAC/50Hz
TRIPLE BAND RF SIGNAL GENERATOR UNIT
•
Five-Signal Output Ports
•
Impedance: 50 ±10%
•
Output Power: -20dBm ~ 0dBm, -15dBm ~ +5dBm, -30dBm ~ -10dBm
•
Frequency Range: 2 x 850MHz ~ 950MHz, 2x 2300MHz ~ 2500MHz, 70.7MHz IF/FM
•
Resolution: 1MHz
•
Sweep Step Size: 1MHz
•
Frequency Accuracy: ±50kHz
•
Frequency Accuracy: ±50kHz
•
Signal Phase Noise: 850MHz ~ 950MHz:-110dBc/Hz @ 100kHz, 2300MHz ~2500MHz: -105dBc/Hz @ 100kHz, 70.7MHzIF/FM: -110dBc/Hz @ 100kHz
•
FM Frequency Deviation: 20kHz ~ 500kHz
•
Display: LCD Display
•
Power Requirements: 240VAC/50Hz
•
Dimensions: 300 (W) x 150 (H) x 410 (L) mm
•
Weight: Approximate 5 Kg
OTHER REQUIRED TEST INSTRUMENTS ( NOT INCLUDED )
• Spectrum Analyzer (3GHz and above with Tracking Generator)
• Digital Oscilloscope ( 100MHz and above)
MANUAL & ACCESSORIES
• Operation / User Manual x 1
• Lab Experiment Manual (with answer) x 1
• Connecting Lead x 1 set
• Mouting Frame (MR-002) x 1 set(OPTIONAL)